ACSizeCheck

What size AC for Fernley, NV? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Fernley needs

3.5 tons central AC or heat pump, about 40,600 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 592 square feet in this climate. For a single room, size by the room: 20.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Lahontan Dam (9.4 mi away). Jul is the hottest month, averaging a high of 96.4°F and a low of 65.6°F, with about 82 days a year at 90°F or more. That gives a design temperature of 103°F against 75°F inside.

What it costs to run

About 2,027 kWh a year at SEER2 14.3, or roughly $271 at Nevada's average residential rate of 13.36¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Fernley

Of the 40,600 BTU/hr, 20,160 comes through walls, roof and windows on a 103°F afternoon (50%), 13,000 is sun on the house (32%), 2,120 is four people and their appliances, and 5,300 is moisture the coil has to wring out of Fernley's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 35,280 BTU/hr before the moisture allowance.

Other house sizes in Fernley

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,5002 tons2 tons
1,500 sq ft31,0002.5 tons2.5 tons
2,500 sq ft50,1004 tons5 tons
3,000 sq ft59,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 7,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,200 BTU/hr.

Month by month in Fernley

MonthAvg highCooling degree daysAC kWh
Jan46.8°F00
Feb53°F00
Mar61.2°F00
Apr67.3°F46
May76.1°F6691
Jun87.1°F245340
Jul96.4°F496690
Aug94.2°F432600
Sep85.6°F188261
Oct71.5°F2738
Nov57.2°F00
Dec46.3°F00

Jul alone uses 34% of the year's cooling energy. The unit runs the equivalent of 714 hours a year at full output.

Fernley against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Sparks, NV28 mi100°F3 tons
Reno, NV35 mi100°F3 tons
Carson, NV41 mi95°F2.5 tons
Truckee, CA56 mi88°F2 tons
South Lake Tahoe, CA61 mi84°F2 tons
Susanville, CA97 mi93°F2.5 tons

Of 10 Nevada cities here, Fernley has the 6th highest cooling load. The range runs from Carson at 30,700 BTU/hr to Henderson at 55,200.

Where Fernley's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Lahontan Dam, 9.4 miles from the center of Fernley at 4,167 ft above sea level. That is close enough that the station's summers are Fernley's summers.

No other city in this set uses Lahontan Dam, so this sizing is Fernley's alone.

The sun over Fernley in late July

At 39.56°N, the noon sun on 21 July stands 70.8° above the horizon over Fernley and the day runs 14 h 23 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

25,508 people live in Fernley, the 7th largest of the 10 Nevada cities sized on this site. Coordinates used: 39.5648, -119.1894.

Fernley AC sizing questions

What size AC does a 2,000 sq ft house in Fernley, NV need?

About 3.5 tons, for a cooling load of 40,600 BTU/hr on a 103°F design day. That is one ton per 592 square feet in Fernley's climate.

Is 20 BTU per square foot right for Fernley?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Lahontan Dam. For a single room here, plan on 20.3 BTU/hr per square foot.

What does central AC cost to run in Fernley?

About $271 a year: 2,027 kWh at SEER2 14.3 and 13.36¢ per kWh, over 5 cooling months.