What size AC for Escanaba, MI? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Escanaba needs

2 tons central AC or heat pump, about 20,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 108% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,187 square feet in this climate. For a single room, size by the room: 10.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Escanaba (2 mi away). Jul is the hottest month, averaging a high of 76.6°F and a low of 56.4°F, with about 2 days a year at 90°F or more. That gives a design temperature of 81°F against 75°F inside.

What it costs to run

About 262 kWh a year at SEER2 14.3, or roughly $57 at Michigan's average residential rate of 21.73¢ per kWh. Cooling runs 2 months of the year here.

What drives the load in Escanaba

Of the 20,200 BTU/hr, 4,320 comes through walls, roof and windows on a 81°F afternoon (21%), 13,000 is sun on the house (64%), 2,120 is four people and their appliances, and 800 is moisture the coil has to wring out of Escanaba's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 19,440 BTU/hr before the moisture allowance.

Other house sizes in Escanaba

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft11,2001.5 tons2 tons
1,500 sq ft15,7001.5 tons2.5 tons
2,500 sq ft24,7002 tons5 tons
3,000 sq ft29,2002.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,500 BTU/hr; a 350 sq ft living room needs about 3,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 6,100 BTU/hr.

Month by month in Escanaba

MonthAvg highCooling degree daysAC kWh
Jan25.6°F00
Feb27.8°F00
Mar36.7°F00
Apr47.3°F00
May60.3°F00
Jun70.5°F2936
Jul76.6°F92115
Aug75.6°F6886
Sep67.6°F1924
Oct54.5°F11
Nov42.2°F00
Dec31.1°F00

Jul alone uses 44% of the year's cooling energy. The unit runs the equivalent of 185 hours a year at full output.

Escanaba against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Marinette, WI53 mi84°F2 tons
Marquette, MI58 mi79°F1.5 tons
Suamico, WI90 mi85°F2 tons
Howard, WI95 mi85°F2 tons
Green Bay, WI95 mi85°F2 tons
Bellevue, WI98 mi85°F2 tons

Of 90 Michigan cities here, Escanaba has the 89th highest cooling load. The range runs from Marquette at 18,700 BTU/hr to Ypsilanti at 28,800.

Where Escanaba's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Escanaba, 2 miles from the center of Escanaba at 590 ft above sea level. That is close enough that the station's summers are Escanaba's summers.

No other city in this set uses Escanaba, so this sizing is Escanaba's alone.

The sun over Escanaba in late July

At 45.75°N, the noon sun on 21 July stands 64.7° above the horizon over Escanaba and the day runs 14 h 60 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

12,296 people live in Escanaba, the 74th largest of the 90 Michigan cities sized on this site. Coordinates used: 45.7463, -87.0836.

Escanaba AC sizing questions

What size AC does a 2,000 sq ft house in Escanaba, MI need?

About 2 tons, for a cooling load of 20,200 BTU/hr on a 81°F design day. That is one ton per 1,187 square feet in Escanaba's climate.

Is 20 BTU per square foot right for Escanaba?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Escanaba. For a single room here, plan on 10.1 BTU/hr per square foot.

What does central AC cost to run in Escanaba?

About $57 a year: 262 kWh at SEER2 14.3 and 21.73¢ per kWh, over 2 cooling months.