ACSizeCheck

What size AC for El Dorado, KS? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in El Dorado needs

3.5 tons central AC or heat pump, about 37,800 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 635 square feet in this climate. For a single room, size by the room: 18.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at El Dorado (1 mi away). Jul is the hottest month, averaging a high of 91.3°F and a low of 68.8°F, with about 54 days a year at 90°F or more. That gives a design temperature of 97°F against 75°F inside.

What it costs to run

About 2,321 kWh a year at SEER2 14.3, or roughly $354 at Kansas's average residential rate of 15.26¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in El Dorado

Of the 37,800 BTU/hr, 15,840 comes through walls, roof and windows on a 97°F afternoon (42%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 6,800 is moisture the coil has to wring out of El Dorado's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,960 BTU/hr before the moisture allowance.

Other house sizes in El Dorado

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,2002 tons2 tons
1,500 sq ft29,0002.5 tons2.5 tons
2,500 sq ft46,6004 tons5 tons
3,000 sq ft55,4005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,300 BTU/hr.

Month by month in El Dorado

MonthAvg highCooling degree daysAC kWh
Jan44.1°F00
Feb48.9°F00
Mar58.9°F35
Apr68.4°F2131
May76.9°F113166
Jun86.3°F312459
Jul91.3°F467688
Aug90.3°F421620
Sep82.7°F201296
Oct71.1°F3652
Nov57.8°F23
Dec46.4°F00

Jul alone uses 30% of the year's cooling energy. The unit runs the equivalent of 879 hours a year at full output.

El Dorado against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Andover, KS17 mi98°F3.5 tons
Bel Aire, KS21 mi98°F3.5 tons
Wichita, KS28 mi99°F3.5 tons
Derby, KS28 mi99°F3.5 tons
Newton, KS30 mi98°F3.5 tons
Haysville, KS32 mi99°F3.5 tons

Of 38 Kansas cities here, El Dorado has the 17th highest cooling load. The range runs from Pittsburg at 33,100 BTU/hr to Wichita at 39,500.

Where El Dorado's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is El Dorado, 1 miles from the center of El Dorado at 1,290 ft above sea level. That is close enough that the station's summers are El Dorado's summers.

No other city in this set uses El Dorado, so this sizing is El Dorado's alone.

The sun over El Dorado in late July

At 37.82°N, the noon sun on 21 July stands 72.6° above the horizon over El Dorado and the day runs 14 h 14 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,694 people live in El Dorado, the 29th largest of the 38 Kansas cities sized on this site. Coordinates used: 37.8204, -96.8630.

El Dorado AC sizing questions

What size AC does a 2,000 sq ft house in El Dorado, KS need?

About 3.5 tons, for a cooling load of 37,800 BTU/hr on a 97°F design day. That is one ton per 635 square feet in El Dorado's climate.

Is 20 BTU per square foot right for El Dorado?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at El Dorado. For a single room here, plan on 18.9 BTU/hr per square foot.

What does central AC cost to run in El Dorado?

About $354 a year: 2,321 kWh at SEER2 14.3 and 15.26¢ per kWh, over 5 cooling months.