What size AC for Dublin, GA? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Dublin needs

3.5 tons central AC or heat pump, about 41,300 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 581 square feet in this climate. For a single room, size by the room: 20.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Dublin (2.1 mi away). Jul is the hottest month, averaging a high of 94°F and a low of 71°F, with about 83 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.

What it costs to run

About 3,343 kWh a year at SEER2 14.3, or roughly $517 at Georgia's average residential rate of 15.48¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Dublin

Of the 41,300 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (45%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 7,400 is moisture the coil has to wring out of Dublin's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.

Other house sizes in Dublin

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,9002 tons2 tons
1,500 sq ft31,6003 tons2.5 tons
2,500 sq ft51,0004 tons5 tons
3,000 sq ft60,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,100 BTU/hr; a 350 sq ft living room needs about 7,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,400 BTU/hr.

Month by month in Dublin

MonthAvg highCooling degree daysAC kWh
Jan58.3°F11
Feb62°F34
Mar70.7°F2029
Apr78.3°F80118
May85.6°F246363
Jun90.7°F426628
Jul94°F542800
Aug92.2°F505745
Sep87°F325479
Oct77.9°F99146
Nov68.5°F1724
Dec60.6°F35

Jul alone uses 24% of the year's cooling energy. The unit runs the equivalent of 1,158 hours a year at full output.

Dublin against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Vidalia, GA38 mi99°F4 tons
Milledgeville, GA42 mi100°F3.5 tons
Warner Robins, GA42 mi100°F3.5 tons
Perry, GA47 mi100°F3.5 tons
Macon-Bibb County, GA48 mi100°F3.5 tons
Statesboro, GA68 mi99°F3.5 tons

Of 101 Georgia cities here, Dublin has the 14th highest cooling load. The range runs from Cumming at 33,100 BTU/hr to Albany at 44,000.

Where Dublin's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Dublin, 2.1 miles from the center of Dublin at 230 ft above sea level. That is close enough that the station's summers are Dublin's summers.

No other city in this set uses Dublin, so this sizing is Dublin's alone.

The sun over Dublin in late July

At 32.54°N, the noon sun on 21 July stands 77.9° above the horizon over Dublin and the day runs 13 h 50 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

16,233 people live in Dublin, the 75th largest of the 101 Georgia cities sized on this site. Coordinates used: 32.5355, -82.9288.

Dublin AC sizing questions

What size AC does a 2,000 sq ft house in Dublin, GA need?

About 3.5 tons, for a cooling load of 41,300 BTU/hr on a 101°F design day. That is one ton per 581 square feet in Dublin's climate.

Is 20 BTU per square foot right for Dublin?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Dublin. For a single room here, plan on 20.6 BTU/hr per square foot.

What does central AC cost to run in Dublin?

About $517 a year: 3,343 kWh at SEER2 14.3 and 15.48¢ per kWh, over 7 cooling months.