ACSizeCheck

What size AC for Douglas, GA? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Douglas needs

3.5 tons central AC or heat pump, about 39,500 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.3 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 607 square feet in this climate. For a single room, size by the room: 19.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Douglas (2.3 mi away). Jul is the hottest month, averaging a high of 92.1°F and a low of 71.6°F, with about 98 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 3,554 kWh a year at SEER2 14.3, or roughly $550 at Georgia's average residential rate of 15.48¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Douglas

Of the 39,500 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (44%), 13,000 is sun on the house (33%), 2,120 is four people and their appliances, and 7,100 is moisture the coil has to wring out of Douglas's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Douglas

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,1002 tons2 tons
1,500 sq ft30,3002.5 tons2.5 tons
2,500 sq ft48,8004 tons5 tons
3,000 sq ft58,0005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 6,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,900 BTU/hr.

Month by month in Douglas

MonthAvg highCooling degree daysAC kWh
Jan60.4°F57
Feb64.3°F711
Mar71.5°F3145
Apr78.5°F97143
May85.9°F283417
Jun90.4°F441650
Jul92.1°F522770
Aug91.1°F502740
Sep86.9°F351518
Oct79°F139205
Nov69.6°F2537
Dec63.1°F812

Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,286 hours a year at full output.

Douglas against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Waycross, GA36 mi102°F4 tons
Tifton, GA39 mi96°F3.5 tons
Valdosta, GA52 mi99°F3.5 tons
Vidalia, GA56 mi99°F4 tons
Jesup, GA57 mi100°F3.5 tons
Moultrie, GA60 mi97°F3.5 tons

Of 101 Georgia cities here, Douglas has the 23rd highest cooling load. The range runs from Cumming at 33,100 BTU/hr to Albany at 44,000.

Where Douglas's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Douglas, 2.3 miles from the center of Douglas at 233 ft above sea level. That is close enough that the station's summers are Douglas's summers.

No other city in this set uses Douglas, so this sizing is Douglas's alone.

The sun over Douglas in late July

At 31.51°N, the noon sun on 21 July stands 78.9° above the horizon over Douglas and the day runs 13 h 45 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

11,828 people live in Douglas, the 91st largest of the 101 Georgia cities sized on this site. Coordinates used: 31.5061, -82.8543.

Douglas AC sizing questions

What size AC does a 2,000 sq ft house in Douglas, GA need?

About 3.5 tons, for a cooling load of 39,500 BTU/hr on a 99°F design day. That is one ton per 607 square feet in Douglas's climate.

Is 20 BTU per square foot right for Douglas?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Douglas. For a single room here, plan on 19.8 BTU/hr per square foot.

What does central AC cost to run in Douglas?

About $550 a year: 3,554 kWh at SEER2 14.3 and 15.48¢ per kWh, over 7 cooling months.