What size AC for Dixon, IL? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Dixon needs
2.5 tons central AC or heat pump, about 27,300 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 878 square feet in this climate. For a single room, size by the room: 13.7 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Dixon 1w (1.9 mi away). Jul is the hottest month, averaging a high of 82.7°F and a low of 64.3°F, with about 11 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.
What it costs to run
About 1,183 kWh a year at SEER2 14.3, or roughly $228 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Dixon
Of the 27,300 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (32%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 3,600 is moisture the coil has to wring out of Dixon's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.
Other house sizes in Dixon
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,900 | 1.5 tons | 2 tons |
| 1,500 sq ft | 21,100 | 2 tons | 2.5 tons |
| 2,500 sq ft | 33,500 | 3 tons | 5 tons |
| 3,000 sq ft | 39,800 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.
Month by month in Dixon
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 29°F | 0 | 0 |
| Feb | 33.6°F | 0 | 0 |
| Mar | 46.3°F | 1 | 2 |
| Apr | 59.9°F | 7 | 9 |
| May | 71°F | 60 | 83 |
| Jun | 79.8°F | 188 | 261 |
| Jul | 82.7°F | 267 | 371 |
| Aug | 81.4°F | 223 | 310 |
| Sep | 75.3°F | 93 | 129 |
| Oct | 62.8°F | 13 | 18 |
| Nov | 47.6°F | 0 | 0 |
| Dec | 34.5°F | 0 | 0 |
Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 619 hours a year at full output.
Dixon against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Sterling, IL | 12 mi | 87°F | 2.5 tons |
| Freeport, IL | 32 mi | 87°F | 2 tons |
| Rockford, IL | 36 mi | 88°F | 2.5 tons |
| DeKalb, IL | 38 mi | 86°F | 2 tons |
| Clinton, IA | 39 mi | 88°F | 2.5 tons |
| Belvidere, IL | 42 mi | 88°F | 2.5 tons |
Of 225 Illinois cities here, Dixon has the 164th highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.
Where Dixon's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Dixon 1w, 1.9 miles from the center of Dixon at 660 ft above sea level. That is close enough that the station's summers are Dixon's summers.
1 other city uses the same station and get the same climate inputs. The closest to Dixon: Sterling (12 mi away, 9.7 mi from the station). Dixon sits closer to the station than any of them, so its numbers are the best measured of the group.
The sun over Dixon in late July
At 41.84°N, the noon sun on 21 July stands 68.6° above the horizon over Dixon and the day runs 14 h 36 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
15,156 people live in Dixon, the 162nd largest of the 225 Illinois cities sized on this site. Coordinates used: 41.8433, -89.4775.
Dixon AC sizing questions
What size AC does a 2,000 sq ft house in Dixon, IL need?
About 2.5 tons, for a cooling load of 27,300 BTU/hr on a 87°F design day. That is one ton per 878 square feet in Dixon's climate.
Is 20 BTU per square foot right for Dixon?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Dixon 1w. For a single room here, plan on 13.7 BTU/hr per square foot.
What does central AC cost to run in Dixon?
About $228 a year: 1,183 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.