What size AC for Dickinson, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Dickinson needs
4 tons central AC or heat pump, about 44,000 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.7 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 546 square feet in this climate. For a single room, size by the room: 22 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Houston Clover Field (12.1 mi away). Aug is the hottest month, averaging a high of 94°F and a low of 76.2°F, with about 101 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.
What it costs to run
About 5,331 kWh a year at SEER2 14.3, or roughly $855 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.
What drives the load in Dickinson
Of the 44,000 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (43%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 10,200 is moisture the coil has to wring out of Dickinson's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.
Other house sizes in Dickinson
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 23,400 | 2 tons | 2 tons |
| 1,500 sq ft | 33,700 | 3 tons | 2.5 tons |
| 2,500 sq ft | 54,300 | 5 tons | 5 tons |
| 3,000 sq ft | 64,600 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,300 BTU/hr; a 350 sq ft living room needs about 7,700 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,200 BTU/hr.
Month by month in Dickinson
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 64.6°F | 21 | 33 |
| Feb | 68.3°F | 39 | 61 |
| Mar | 74°F | 94 | 148 |
| Apr | 79.5°F | 189 | 297 |
| May | 86°F | 396 | 622 |
| Jun | 91.4°F | 550 | 865 |
| Jul | 93.3°F | 612 | 962 |
| Aug | 94°F | 623 | 979 |
| Sep | 89.9°F | 483 | 759 |
| Oct | 82.9°F | 268 | 421 |
| Nov | 73.3°F | 83 | 130 |
| Dec | 66.4°F | 35 | 55 |
Aug alone uses 18% of the year's cooling energy. The unit runs the equivalent of 1,733 hours a year at full output.
Dickinson against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| League City, TX | 4 mi | 101°F | 4 tons |
| Santa Fe, TX | 5 mi | 101°F | 4 tons |
| Webster, TX | 7 mi | 101°F | 4 tons |
| La Marque, TX | 7 mi | 98°F | 3.5 tons |
| Friendswood, TX | 10 mi | 101°F | 4 tons |
| Texas City, TX | 10 mi | 96°F | 3.5 tons |
Of 252 Texas cities here, Dickinson has the 189th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Dickinson's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Houston Clover Field, 12.1 miles from the center of Dickinson at 39 ft above sea level. That is close enough that the station's summers are Dickinson's summers.
9 other cities use the same station and get the same climate inputs. The closest to Dickinson: League City (4 mi away, 8.3 mi from the station), Santa Fe (5 mi away, 12.4 mi from the station), Webster (7 mi away, 7.6 mi from the station), Friendswood (10 mi away, 2.6 mi from the station), Alvin (10 mi away, 6.6 mi from the station). Dickinson is farther from the station than 6 of them.
The sun over Dickinson in late July
At 29.45°N, the noon sun on 21 July stands 80.9° above the horizon over Dickinson and the day runs 13 h 37 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.
21,941 people live in Dickinson, the 145th largest of the 252 Texas cities sized on this site. Coordinates used: 29.4517, -95.0562.
Dickinson AC sizing questions
What size AC does a 2,000 sq ft house in Dickinson, TX need?
About 4 tons, for a cooling load of 44,000 BTU/hr on a 101°F design day. That is one ton per 546 square feet in Dickinson's climate.
Is 20 BTU per square foot right for Dickinson?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Houston Clover Field. For a single room here, plan on 22 BTU/hr per square foot.
What does central AC cost to run in Dickinson?
About $855 a year: 5,331 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.