ACSizeCheck

What size AC for Dickinson, ND? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Dickinson needs

2.5 tons central AC or heat pump, about 26,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 60% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 916 square feet in this climate. For a single room, size by the room: 13.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Dickinson Theodore Roosevelt R (6.4 mi away). Jul is the hottest month, averaging a high of 83.9°F and a low of 55°F, with about 20 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 526 kWh a year at SEER2 14.3, or roughly $66 at North Dakota's average residential rate of 12.46¢ per kWh. Cooling runs 2 months of the year here.

What drives the load in Dickinson

Of the 26,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (38%), 13,000 is sun on the house (50%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Dickinson's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Dickinson

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,2001.5 tons2 tons
1,500 sq ft20,2002 tons2.5 tons
2,500 sq ft32,2003 tons5 tons
3,000 sq ft38,2003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Dickinson

MonthAvg highCooling degree daysAC kWh
Jan26.6°F00
Feb30.2°F00
Mar42.1°F00
Apr54.7°F00
May66.1°F911
Jun75.6°F4962
Jul83.9°F167210
Aug83.7°F154193
Sep73°F3948
Oct56.4°F22
Nov41.3°F00
Dec30.1°F00

Jul alone uses 40% of the year's cooling energy. The unit runs the equivalent of 287 hours a year at full output.

Dickinson against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Mandan, ND90 mi89°F2.5 tons
Bismarck, ND96 mi89°F2.5 tons
Williston, ND98 mi89°F2.5 tons
Minot, ND117 mi88°F2.5 tons
Spearfish, SD173 mi88°F2 tons
Box Elder, SD193 mi91°F2.5 tons

Of 9 North Dakota cities here, Dickinson has the 4th highest cooling load. The range runs from Grand Forks at 23,200 BTU/hr to Minot at 26,400.

Where Dickinson's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Dickinson Theodore Roosevelt R, 6.4 miles from the center of Dickinson at 2,583 ft above sea level. That is close enough that the station's summers are Dickinson's summers.

No other city in this set uses Dickinson Theodore Roosevelt R, so this sizing is Dickinson's alone.

The sun over Dickinson in late July

At 46.89°N, the noon sun on 21 July stands 63.5° above the horizon over Dickinson and the day runs 15 h 07 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

25,695 people live in Dickinson, the 7th largest of the 9 North Dakota cities sized on this site. Coordinates used: 46.8928, -102.7960.

Dickinson AC sizing questions

What size AC does a 2,000 sq ft house in Dickinson, ND need?

About 2.5 tons, for a cooling load of 26,200 BTU/hr on a 89°F design day. That is one ton per 916 square feet in Dickinson's climate.

Is 20 BTU per square foot right for Dickinson?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Dickinson Theodore Roosevelt R. For a single room here, plan on 13.1 BTU/hr per square foot.

What does central AC cost to run in Dickinson?

About $66 a year: 526 kWh at SEER2 14.3 and 12.46¢ per kWh, over 2 cooling months.