What size AC for Deming, NM? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Deming needs

3.5 tons central AC or heat pump, about 38,900 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.2 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 617 square feet in this climate. For a single room, size by the room: 19.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Deming Municipal Airport (1.9 mi away). Jun is the hottest month, averaging a high of 96.1°F and a low of 61.1°F, with about 106 days a year at 90°F or more. That gives a design temperature of 104°F against 75°F inside.

What it costs to run

About 2,369 kWh a year at SEER2 14.3, or roughly $363 at New Mexico's average residential rate of 15.34¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Deming

Of the 38,900 BTU/hr, 20,880 comes through walls, roof and windows on a 104°F afternoon (54%), 13,000 is sun on the house (33%), 2,120 is four people and their appliances, and 2,900 is moisture the coil has to wring out of Deming's summer air (7%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,000 BTU/hr before the moisture allowance.

Other house sizes in Deming

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,6002 tons2 tons
1,500 sq ft29,7002.5 tons2.5 tons
2,500 sq ft48,0004 tons5 tons
3,000 sq ft57,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,900 BTU/hr; a 350 sq ft living room needs about 6,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,600 BTU/hr.

Month by month in Deming

MonthAvg highCooling degree daysAC kWh
Jan57.6°F00
Feb62.2°F00
Mar69.9°F11
Apr77.5°F1722
May86.7°F147191
Jun96.1°F408532
Jul95.5°F508663
Aug92.8°F445580
Sep87.5°F246321
Oct78.2°F4356
Nov66.4°F11
Dec56.7°F00

Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 871 hours a year at full output.

Deming against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Las Cruces, NM56 mi104°F3.5 tons
Sunland Park, NM74 mi105°F4 tons
El Paso, TX83 mi105°F4 tons
Socorro, TX98 mi105°F4 tons
San Elizario, TX99 mi105°F4 tons
Horizon City, TX100 mi105°F4 tons

Of 19 New Mexico cities here, Deming has the 8th highest cooling load. The range runs from Las Vegas at 25,500 BTU/hr to Sunland Park at 44,800.

Where Deming's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Deming Municipal Airport, 1.9 miles from the center of Deming at 4,303 ft above sea level. That is close enough that the station's summers are Deming's summers.

No other city in this set uses Deming Municipal Airport, so this sizing is Deming's alone.

The sun over Deming in late July

At 32.26°N, the noon sun on 21 July stands 78.1° above the horizon over Deming and the day runs 13 h 49 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

15,272 people live in Deming, the 14th largest of the 19 New Mexico cities sized on this site. Coordinates used: 32.2631, -107.7525.

Deming AC sizing questions

What size AC does a 2,000 sq ft house in Deming, NM need?

About 3.5 tons, for a cooling load of 38,900 BTU/hr on a 104°F design day. That is one ton per 617 square feet in Deming's climate.

Is 20 BTU per square foot right for Deming?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Deming Municipal Airport. For a single room here, plan on 19.4 BTU/hr per square foot.

What does central AC cost to run in Deming?

About $363 a year: 2,369 kWh at SEER2 14.3 and 15.34¢ per kWh, over 5 cooling months.