What size AC for Danville, IN? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Danville needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Indianapolis Eagle Creek Airport (11.5 mi away). Jul is the hottest month, averaging a high of 85.2°F and a low of 66.7°F, with about 17 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,566 kWh a year at SEER2 14.3, or roughly $267 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Danville

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of Danville's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in Danville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in Danville

MonthAvg highCooling degree daysAC kWh
Jan36.4°F00
Feb41°F00
Mar52.1°F34
Apr64°F1419
May73.8°F87120
Jun82.1°F239332
Jul85.2°F340473
Aug84°F292405
Sep78.1°F133185
Oct65.6°F2028
Nov52°F00
Dec40.8°F00

Jul alone uses 30% of the year's cooling energy. The unit runs the equivalent of 751 hours a year at full output.

Danville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Avon, IN5 mi90°F2.5 tons
Brownsburg, IN8 mi90°F2.5 tons
Plainfield, IN8 mi90°F2.5 tons
Mooresville, IN13 mi90°F2.5 tons
Speedway, IN13 mi90°F2.5 tons
Whitestown, IN16 mi90°F2.5 tons

Of 88 Indiana cities here, Danville has the 48th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Danville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Indianapolis Eagle Creek Airport, 11.5 miles from the center of Danville at 812 ft above sea level. That is close enough that the station's summers are Danville's summers.

11 other cities use the same station and get the same climate inputs. The closest to Danville: Avon (5 mi away, 6.8 mi from the station), Brownsburg (8 mi away, 4.8 mi from the station), Speedway (13 mi away, 3.3 mi from the station), Whitestown (16 mi away, 10.9 mi from the station), Zionsville (19 mi away, 11.6 mi from the station). Danville is farther from the station than 4 of them.

The sun over Danville in late July

At 39.76°N, the noon sun on 21 July stands 70.6° above the horizon over Danville and the day runs 14 h 24 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,532 people live in Danville, the 71st largest of the 88 Indiana cities sized on this site. Coordinates used: 39.7588, -86.4953.

Danville AC sizing questions

What size AC does a 2,000 sq ft house in Danville, IN need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in Danville's climate.

Is 20 BTU per square foot right for Danville?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Indianapolis Eagle Creek Airport. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in Danville?

About $267 a year: 1,566 kWh at SEER2 14.3 and 17.04¢ per kWh, over 5 cooling months.