What size AC for Cookeville, TN? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Cookeville needs

3 tons central AC or heat pump, about 31,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 33% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 763 square feet in this climate. For a single room, size by the room: 15.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cookeville (2.8 mi away). Jul is the hottest month, averaging a high of 87.3°F and a low of 66.1°F, with about 29 days a year at 90°F or more. That gives a design temperature of 92°F against 75°F inside.

What it costs to run

About 1,764 kWh a year at SEER2 14.3, or roughly $243 at Tennessee's average residential rate of 13.8¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Cookeville

Of the 31,500 BTU/hr, 12,240 comes through walls, roof and windows on a 92°F afternoon (39%), 13,000 is sun on the house (41%), 2,120 is four people and their appliances, and 4,100 is moisture the coil has to wring out of Cookeville's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 27,360 BTU/hr before the moisture allowance.

Other house sizes in Cookeville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft17,0001.5 tons2 tons
1,500 sq ft24,2002 tons2.5 tons
2,500 sq ft38,7003.5 tons5 tons
3,000 sq ft46,0004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,400 BTU/hr.

Month by month in Cookeville

MonthAvg highCooling degree daysAC kWh
Jan47.1°F00
Feb51.4°F00
Mar60°F34
Apr69.8°F1824
May77.5°F100139
Jun84.3°F250348
Jul87.3°F363504
Aug86.9°F328456
Sep81.9°F172239
Oct71.9°F3345
Nov60.4°F34
Dec50.9°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 802 hours a year at full output.

Cookeville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Crossville, TN30 mi87°F2.5 tons
McMinnville, TN35 mi94°F3 tons
Hartsville/Trousdale County, TN40 mi94°F3 tons
Lebanon, TN47 mi96°F3.5 tons
Murfreesboro, TN55 mi95°F3 tons
Gallatin, TN56 mi97°F3.5 tons

Of 65 Tennessee cities here, Cookeville has the 54th highest cooling load. The range runs from Crossville at 27,300 BTU/hr to Memphis at 41,200.

Where Cookeville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cookeville, 2.8 miles from the center of Cookeville at 1,090 ft above sea level. That is close enough that the station's summers are Cookeville's summers.

No other city in this set uses Cookeville, so this sizing is Cookeville's alone.

The sun over Cookeville in late July

At 36.15°N, the noon sun on 21 July stands 74.3° above the horizon over Cookeville and the day runs 14 h 06 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

37,102 people live in Cookeville, the 24th largest of the 65 Tennessee cities sized on this site. Coordinates used: 36.1469, -85.5127.

Cookeville AC sizing questions

What size AC does a 2,000 sq ft house in Cookeville, TN need?

About 3 tons, for a cooling load of 31,500 BTU/hr on a 92°F design day. That is one ton per 763 square feet in Cookeville's climate.

Is 20 BTU per square foot right for Cookeville?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Cookeville. For a single room here, plan on 15.7 BTU/hr per square foot.

What does central AC cost to run in Cookeville?

About $243 a year: 1,764 kWh at SEER2 14.3 and 13.8¢ per kWh, over 5 cooling months.