What size AC for Conway, AR? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Conway needs

3.5 tons central AC or heat pump, about 38,700 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.2 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 621 square feet in this climate. For a single room, size by the room: 19.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Conway (2.4 mi away). Jul is the hottest month, averaging a high of 91.7°F and a low of 69.6°F, with about 70 days a year at 90°F or more. That gives a design temperature of 98°F against 75°F inside.

What it costs to run

About 2,648 kWh a year at SEER2 14.3, or roughly $364 at Arkansas's average residential rate of 13.74¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Conway

Of the 38,700 BTU/hr, 16,560 comes through walls, roof and windows on a 98°F afternoon (43%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 7,000 is moisture the coil has to wring out of Conway's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 31,680 BTU/hr before the moisture allowance.

Other house sizes in Conway

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,6002 tons2 tons
1,500 sq ft29,6002.5 tons2.5 tons
2,500 sq ft47,7004 tons5 tons
3,000 sq ft56,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,900 BTU/hr; a 350 sq ft living room needs about 6,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,600 BTU/hr.

Month by month in Conway

MonthAvg highCooling degree daysAC kWh
Jan49°F00
Feb54.1°F01
Mar63°F710
Apr72°F3551
May79.4°F151223
Jun87.3°F352518
Jul91.7°F485715
Aug91.4°F462681
Sep84.7°F245361
Oct73.9°F5480
Nov61°F57
Dec51.6°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 980 hours a year at full output.

Conway against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Maumelle, AR16 mi97°F3.5 tons
Sherwood, AR21 mi97°F3.5 tons
Jacksonville, AR23 mi97°F3.5 tons
North Little Rock, AR24 mi98°F3.5 tons
Little Rock, AR25 mi98°F3.5 tons
Cabot, AR26 mi99°F3.5 tons

Of 39 Arkansas cities here, Conway has the 19th highest cooling load. The range runs from Harrison at 33,100 BTU/hr to Fort Smith at 44,000.

Where Conway's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Conway, 2.4 miles from the center of Conway at 312 ft above sea level. That is close enough that the station's summers are Conway's summers.

No other city in this set uses Conway, so this sizing is Conway's alone.

The sun over Conway in late July

At 35.07°N, the noon sun on 21 July stands 75.3° above the horizon over Conway and the day runs 14 h 01 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

70,711 people live in Conway, the 7th largest of the 39 Arkansas cities sized on this site. Coordinates used: 35.0744, -92.4670.

Conway AC sizing questions

What size AC does a 2,000 sq ft house in Conway, AR need?

About 3.5 tons, for a cooling load of 38,700 BTU/hr on a 98°F design day. That is one ton per 621 square feet in Conway's climate.

Is 20 BTU per square foot right for Conway?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Conway. For a single room here, plan on 19.3 BTU/hr per square foot.

What does central AC cost to run in Conway?

About $364 a year: 2,648 kWh at SEER2 14.3 and 13.74¢ per kWh, over 6 cooling months.