What size AC for Collingswood, NJ? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Collingswood needs
3 tons central AC or heat pump, about 34,300 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 23% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 701 square feet in this climate. For a single room, size by the room: 17.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Phila International Airport (8.4 mi away). Jul is the hottest month, averaging a high of 87.8°F and a low of 69.6°F, with about 30 days a year at 90°F or more. That gives a design temperature of 93°F against 75°F inside.
What it costs to run
About 2,002 kWh a year at SEER2 14.3, or roughly $482 at New Jersey's average residential rate of 24.09¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Collingswood
Of the 34,300 BTU/hr, 12,960 comes through walls, roof and windows on a 93°F afternoon (38%), 13,000 is sun on the house (38%), 2,120 is four people and their appliances, and 6,200 is moisture the coil has to wring out of Collingswood's summer air (18%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 28,080 BTU/hr before the moisture allowance.
Other house sizes in Collingswood
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 18,400 | 1.5 tons | 2 tons |
| 1,500 sq ft | 26,300 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 42,200 | 4 tons | 5 tons |
| 3,000 sq ft | 50,100 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,300 BTU/hr.
Month by month in Collingswood
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 41.3°F | 0 | 0 |
| Feb | 44.3°F | 0 | 0 |
| Mar | 52.8°F | 1 | 1 |
| Apr | 64.7°F | 15 | 22 |
| May | 74.4°F | 82 | 121 |
| Jun | 83.2°F | 266 | 393 |
| Jul | 87.8°F | 425 | 626 |
| Aug | 85.8°F | 368 | 542 |
| Sep | 78.9°F | 175 | 259 |
| Oct | 67.2°F | 26 | 38 |
| Nov | 55.9°F | 1 | 1 |
| Dec | 46°F | 0 | 0 |
Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 836 hours a year at full output.
Collingswood against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Camden, NJ | 2 mi | 93°F | 3 tons |
| Gloucester City, NJ | 3 mi | 93°F | 3 tons |
| Haddonfield, NJ | 3 mi | 93°F | 3 tons |
| Bellmawr, NJ | 3 mi | 93°F | 3 tons |
| Woodbury, NJ | 7 mi | 93°F | 3 tons |
| Philadelphia, PA | 7 mi | 93°F | 3 tons |
Of 116 New Jersey cities here, Collingswood has the 3rd highest cooling load. The range runs from Hackettstown at 26,400 BTU/hr to Camden at 34,300.
Where Collingswood's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Phila International Airport, across the line in Pennsylvania, 8.4 miles from the center of Collingswood at 7 ft above sea level. That is close enough that the station's summers are Collingswood's summers.
10 other cities use the same station and get the same climate inputs. The closest to Collingswood: Camden (2 mi away, 7.7 mi from the station), Gloucester City (3 mi away, 6 mi from the station), Haddonfield (3 mi away, 10.3 mi from the station), Bellmawr (3 mi away, 7 mi from the station), Woodbury (7 mi away, 4.7 mi from the station). Collingswood is farther from the station than 8 of them.
The sun over Collingswood in late July
At 39.92°N, the noon sun on 21 July stands 70.5° above the horizon over Collingswood and the day runs 14 h 25 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
14,344 people live in Collingswood, the 75th largest of the 116 New Jersey cities sized on this site. Coordinates used: 39.9153, -75.0784.
Collingswood AC sizing questions
What size AC does a 2,000 sq ft house in Collingswood, NJ need?
About 3 tons, for a cooling load of 34,300 BTU/hr on a 93°F design day. That is one ton per 701 square feet in Collingswood's climate.
Is 20 BTU per square foot right for Collingswood?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Phila International Airport. For a single room here, plan on 17.1 BTU/hr per square foot.
What does central AC cost to run in Collingswood?
About $482 a year: 2,002 kWh at SEER2 14.3 and 24.09¢ per kWh, over 5 cooling months.