ACSizeCheck

What size AC for Coachella, CA? 5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Coachella needs

5 tons central AC or heat pump, about 57,100 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 420 square feet in this climate. For a single room, size by the room: 28.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Desert Resorts Regional Airport (4.2 mi away). Jul is the hottest month, averaging a high of 106.9°F and a low of 75.6°F, with about 187 days a year at 90°F or more. That gives a design temperature of 115°F against 75°F inside.

What it costs to run

About 6,094 kWh a year at SEER2 14.3, or roughly $1,986 at California's average residential rate of 32.58¢ per kWh. Cooling runs 8 months of the year here.

What drives the load in Coachella

Of the 57,100 BTU/hr, 28,800 comes through walls, roof and windows on a 115°F afternoon (50%), 13,000 is sun on the house (23%), 2,120 is four people and their appliances, and 13,200 is moisture the coil has to wring out of Coachella's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 43,920 BTU/hr before the moisture allowance.

Other house sizes in Coachella

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft29,9002.5 tons2 tons
1,500 sq ft43,5004 tons2.5 tons
2,500 sq ft70,7005 tons5 tons
3,000 sq ft84,3005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 4,300 BTU/hr; a 350 sq ft living room needs about 10,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 17,100 BTU/hr.

Month by month in Coachella

MonthAvg highCooling degree daysAC kWh
Jan71°F23
Feb74.3°F1118
Mar81.1°F79125
Apr87.2°F198312
May94.6°F428673
Jun103°F632992
Jul106.9°F8141,278
Aug106.2°F7921,244
Sep101.5°F596935
Oct90.9°F285448
Nov78.7°F4266
Dec69.3°F11

Jul alone uses 21% of the year's cooling energy. The unit runs the equivalent of 1,526 hours a year at full output.

Coachella against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Indio, CA6 mi115°F5 tons
La Quinta, CA8 mi115°F5 tons
Palm Desert, CA13 mi117°F5 tons
Rancho Mirage, CA17 mi117°F5 tons
Cathedral City, CA21 mi117°F5 tons
Palm Springs, CA24 mi117°F5 tons

Of 376 California cities here, Coachella has the 12th highest cooling load. The range runs from Corte Madera at 15,700 BTU/hr to Palm Desert at 59,000.

Where Coachella's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Desert Resorts Regional Airport, 4.2 miles from the center of Coachella at -118 ft above sea level. That is close enough that the station's summers are Coachella's summers.

2 other cities use the same station and get the same climate inputs. The closest to Coachella: Indio (6 mi away, 8 mi from the station), La Quinta (8 mi away, 6.4 mi from the station). Coachella sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Coachella in late July

At 33.69°N, the noon sun on 21 July stands 76.7° above the horizon over Coachella and the day runs 13 h 55 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

45,165 people live in Coachella, the 195th largest of the 376 California cities sized on this site. Coordinates used: 33.6904, -116.1431.

Coachella AC sizing questions

What size AC does a 2,000 sq ft house in Coachella, CA need?

About 5 tons, for a cooling load of 57,100 BTU/hr on a 115°F design day. That is one ton per 420 square feet in Coachella's climate.

Is 20 BTU per square foot right for Coachella?

The chart gives 3.5 tons for 2,000 sq ft, against 5 tons sized from NOAA's 1991 to 2020 normals at Desert Resorts Regional Airport. For a single room here, plan on 28.5 BTU/hr per square foot.

What does central AC cost to run in Coachella?

About $1,986 a year: 6,094 kWh at SEER2 14.3 and 32.58¢ per kWh, over 8 cooling months.