ACSizeCheck

What size AC for Clute, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Clute needs

4 tons central AC or heat pump, about 43,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.6 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 557 square feet in this climate. For a single room, size by the room: 21.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Angleton Lake Jackson Brazoria C (7.3 mi away). Aug is the hottest month, averaging a high of 93.2°F and a low of 74.6°F, with about 94 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.

What it costs to run

About 5,056 kWh a year at SEER2 14.3, or roughly $810 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.

What drives the load in Clute

Of the 43,100 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (42%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 9,900 is moisture the coil has to wring out of Clute's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.

Other house sizes in Clute

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,9002 tons2 tons
1,500 sq ft33,0003 tons2.5 tons
2,500 sq ft53,1005 tons5 tons
3,000 sq ft63,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,900 BTU/hr.

Month by month in Clute

MonthAvg highCooling degree daysAC kWh
Jan65.3°F2336
Feb68.5°F3961
Mar73.9°F88137
Apr79.4°F175275
May85.9°F375589
Jun90.9°F514808
Jul92.8°F584918
Aug93.2°F586920
Sep89.4°F453712
Oct83.5°F259406
Nov74.2°F86136
Dec67.4°F3758

Aug alone uses 18% of the year's cooling energy. The unit runs the equivalent of 1,679 hours a year at full output.

Clute against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lake Jackson, TX4 mi100°F4 tons
Freeport, TX6 mi100°F4 tons
Angleton, TX10 mi100°F4 tons
Galveston, TX28 mi98°F3.5 tons
Iowa Colony, TX29 mi101°F4 tons
Alvin, TX29 mi101°F4 tons

Of 252 Texas cities here, Clute has the 216th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Clute's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Angleton Lake Jackson Brazoria C, 7.3 miles from the center of Clute at 25 ft above sea level. That is close enough that the station's summers are Clute's summers.

3 other cities use the same station and get the same climate inputs. The closest to Clute: Lake Jackson (4 mi away, 4.5 mi from the station), Freeport (6 mi away, 13.5 mi from the station), Angleton (10 mi away, 4.4 mi from the station). Clute is farther from the station than 2 of them.

The sun over Clute in late July

At 29.03°N, the noon sun on 21 July stands 81.4° above the horizon over Clute and the day runs 13 h 35 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

10,893 people live in Clute, the 235th largest of the 252 Texas cities sized on this site. Coordinates used: 29.0259, -95.3982.

Clute AC sizing questions

What size AC does a 2,000 sq ft house in Clute, TX need?

About 4 tons, for a cooling load of 43,100 BTU/hr on a 100°F design day. That is one ton per 557 square feet in Clute's climate.

Is 20 BTU per square foot right for Clute?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Angleton Lake Jackson Brazoria C. For a single room here, plan on 21.5 BTU/hr per square foot.

What does central AC cost to run in Clute?

About $810 a year: 5,056 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.