ACSizeCheck

What size AC for Cleveland, TN? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Cleveland needs

3 tons central AC or heat pump, about 33,100 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 27% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 725 square feet in this climate. For a single room, size by the room: 16.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cleveland Fltr Plt (5.2 mi away). Jul is the hottest month, averaging a high of 89°F and a low of 67.8°F, with about 36 days a year at 90°F or more. That gives a design temperature of 94°F against 75°F inside.

What it costs to run

About 2,142 kWh a year at SEER2 14.3, or roughly $296 at Tennessee's average residential rate of 13.8¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Cleveland

Of the 33,100 BTU/hr, 13,680 comes through walls, roof and windows on a 94°F afternoon (41%), 13,000 is sun on the house (39%), 2,120 is four people and their appliances, and 4,300 is moisture the coil has to wring out of Cleveland's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 28,800 BTU/hr before the moisture allowance.

Other house sizes in Cleveland

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft17,8001.5 tons2 tons
1,500 sq ft25,4002 tons2.5 tons
2,500 sq ft40,8003.5 tons5 tons
3,000 sq ft48,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,500 BTU/hr; a 350 sq ft living room needs about 5,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,000 BTU/hr.

Month by month in Cleveland

MonthAvg highCooling degree daysAC kWh
Jan50°F00
Feb54.6°F11
Mar62.7°F68
Apr72.4°F3447
May79.5°F133184
Jun86.1°F304422
Jul89°F415577
Aug88.4°F391543
Sep83°F214297
Oct73°F4056
Nov61.3°F45
Dec52.6°F11

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 925 hours a year at full output.

Cleveland against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Collegedale, TN13 mi96°F3.5 tons
Soddy-Daisy, TN18 mi96°F3.5 tons
Chattanooga, TN23 mi96°F3.5 tons
East Ridge, TN24 mi96°F3.5 tons
Athens, TN24 mi94°F3 tons
Red Bank, TN24 mi96°F3.5 tons

Of 65 Tennessee cities here, Cleveland has the 47th highest cooling load. The range runs from Crossville at 27,300 BTU/hr to Memphis at 41,200.

Where Cleveland's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cleveland Fltr Plt, 5.2 miles from the center of Cleveland at 842 ft above sea level. That is close enough that the station's summers are Cleveland's summers.

No other city in this set uses Cleveland Fltr Plt, so this sizing is Cleveland's alone.

The sun over Cleveland in late July

At 35.18°N, the noon sun on 21 July stands 75.2° above the horizon over Cleveland and the day runs 14 h 02 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

50,232 people live in Cleveland, the 18th largest of the 65 Tennessee cities sized on this site. Coordinates used: 35.1800, -84.8713.

Cleveland AC sizing questions

What size AC does a 2,000 sq ft house in Cleveland, TN need?

About 3 tons, for a cooling load of 33,100 BTU/hr on a 94°F design day. That is one ton per 725 square feet in Cleveland's climate.

Is 20 BTU per square foot right for Cleveland?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Cleveland Fltr Plt. For a single room here, plan on 16.6 BTU/hr per square foot.

What does central AC cost to run in Cleveland?

About $296 a year: 2,142 kWh at SEER2 14.3 and 13.8¢ per kWh, over 5 cooling months.