ACSizeCheck

What size AC for Champaign, IL? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Champaign needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Champaign Urbana Willard Airport (5.6 mi away). Jul is the hottest month, averaging a high of 85°F and a low of 64.4°F, with about 22 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,464 kWh a year at SEER2 14.3, or roughly $282 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Champaign

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of Champaign's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in Champaign

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in Champaign

MonthAvg highCooling degree daysAC kWh
Jan34.1°F00
Feb38.9°F00
Mar51.5°F33
Apr64.7°F1217
May75.5°F99137
Jun83.5°F241334
Jul85°F303421
Aug83.5°F247343
Sep79.4°F124173
Oct66.9°F2635
Nov51.5°F11
Dec39.1°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 703 hours a year at full output.

Champaign against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Urbana, IL4 mi90°F2.5 tons
Mahomet, IL8 mi88°F2.5 tons
Rantoul, IL14 mi93°F3 tons
Danville, IL35 mi90°F2.5 tons
Decatur, IL39 mi91°F2.5 tons
Charleston, IL44 mi90°F2.5 tons

Of 225 Illinois cities here, Champaign has the 43rd highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.

Where Champaign's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Champaign Urbana Willard Airport, 5.6 miles from the center of Champaign at 743 ft above sea level. That is close enough that the station's summers are Champaign's summers.

1 other city uses the same station and get the same climate inputs. The closest to Champaign: Urbana (4 mi away, 6.8 mi from the station). Champaign sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Champaign in late July

At 40.11°N, the noon sun on 21 July stands 70.3° above the horizon over Champaign and the day runs 14 h 26 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

91,961 people live in Champaign, the 9th largest of the 225 Illinois cities sized on this site. Coordinates used: 40.1141, -88.2746.

Champaign AC sizing questions

What size AC does a 2,000 sq ft house in Champaign, IL need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in Champaign's climate.

Is 20 BTU per square foot right for Champaign?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Champaign Urbana Willard Airport. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in Champaign?

About $282 a year: 1,464 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.