ACSizeCheck

What size AC for Casselberry, FL? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Casselberry needs

4 tons central AC or heat pump, about 43,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.6 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 557 square feet in this climate. For a single room, size by the room: 21.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Orlando Executive Airport (8 mi away). Jul is the hottest month, averaging a high of 91.9°F and a low of 75°F, with about 111 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.

What it costs to run

About 5,802 kWh a year at SEER2 14.3, or roughly $889 at Florida's average residential rate of 15.32¢ per kWh. Cooling runs 12 months of the year here.

What drives the load in Casselberry

Of the 43,100 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (42%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 9,900 is moisture the coil has to wring out of Casselberry's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.

Other house sizes in Casselberry

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,9002 tons2 tons
1,500 sq ft33,0003 tons2.5 tons
2,500 sq ft53,1005 tons5 tons
3,000 sq ft63,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,900 BTU/hr.

Month by month in Casselberry

MonthAvg highCooling degree daysAC kWh
Jan71.2°F5687
Feb74.3°F75118
Mar78.4°F145228
Apr83.2°F248389
May88.2°F417655
Jun90.7°F511803
Jul91.9°F572898
Aug91.8°F575903
Sep89.5°F501787
Oct84.4°F356559
Nov77.8°F154242
Dec73.1°F83131

Aug alone uses 16% of the year's cooling energy. The unit runs the equivalent of 1,927 hours a year at full output.

Casselberry against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Longwood, FL3 mi101°F4 tons
Winter Springs, FL4 mi101°F4 tons
Maitland, FL4 mi100°F4 tons
Altamonte Springs, FL4 mi100°F4 tons
Winter Park, FL5 mi100°F4 tons
Lake Mary, FL7 mi101°F4 tons

Of 173 Florida cities here, Casselberry has the 31st highest cooling load. The range runs from Miami Shores at 36,500 BTU/hr to Plant City at 44,900.

Where Casselberry's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Orlando Executive Airport, 8 miles from the center of Casselberry at 104 ft above sea level. That is close enough that the station's summers are Casselberry's summers.

6 other cities use the same station and get the same climate inputs. The closest to Casselberry: Maitland (4 mi away, 6.2 mi from the station), Altamonte Springs (4 mi away, 8.7 mi from the station), Winter Park (5 mi away, 3.5 mi from the station), Apopka (13 mi away, 16 mi from the station), Ocoee (14 mi away, 12.2 mi from the station). Casselberry is farther from the station than 2 of them.

The sun over Casselberry in late July

At 28.66°N, the noon sun on 21 July stands 81.7° above the horizon over Casselberry and the day runs 13 h 34 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

31,650 people live in Casselberry, the 93rd largest of the 173 Florida cities sized on this site. Coordinates used: 28.6612, -81.3219.

Casselberry AC sizing questions

What size AC does a 2,000 sq ft house in Casselberry, FL need?

About 4 tons, for a cooling load of 43,100 BTU/hr on a 100°F design day. That is one ton per 557 square feet in Casselberry's climate.

Is 20 BTU per square foot right for Casselberry?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Orlando Executive Airport. For a single room here, plan on 21.5 BTU/hr per square foot.

What does central AC cost to run in Casselberry?

About $889 a year: 5,802 kWh at SEER2 14.3 and 15.32¢ per kWh, over 12 cooling months.