What size AC for Camden, AR? 3.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Camden needs
3.5 tons central AC or heat pump, about 39,500 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.3 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 607 square feet in this climate. For a single room, size by the room: 19.8 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Camden 1 (2.1 mi away). Aug is the hottest month, averaging a high of 92°F and a low of 69.7°F, with about 82 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.
What it costs to run
About 3,002 kWh a year at SEER2 14.3, or roughly $412 at Arkansas's average residential rate of 13.74¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Camden
Of the 39,500 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (44%), 13,000 is sun on the house (33%), 2,120 is four people and their appliances, and 7,100 is moisture the coil has to wring out of Camden's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.
Other house sizes in Camden
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 21,100 | 2 tons | 2 tons |
| 1,500 sq ft | 30,300 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 48,800 | 4 tons | 5 tons |
| 3,000 sq ft | 58,000 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 6,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,900 BTU/hr.
Month by month in Camden
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 53.3°F | 1 | 2 |
| Feb | 57.9°F | 2 | 3 |
| Mar | 66.4°F | 13 | 19 |
| Apr | 74.5°F | 56 | 83 |
| May | 81.4°F | 194 | 285 |
| Jun | 88.8°F | 393 | 580 |
| Jul | 91.9°F | 512 | 754 |
| Aug | 92°F | 491 | 724 |
| Sep | 86°F | 287 | 423 |
| Oct | 75.7°F | 75 | 110 |
| Nov | 64°F | 10 | 15 |
| Dec | 55.6°F | 2 | 3 |
Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,086 hours a year at full output.
Camden against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| El Dorado, AR | 26 mi | 101°F | 3.5 tons |
| Magnolia, AR | 30 mi | 99°F | 3.5 tons |
| Malvern, AR | 56 mi | 98°F | 3.5 tons |
| Hot Springs, AR | 65 mi | 100°F | 4 tons |
| Pine Bluff, AR | 65 mi | 98°F | 3.5 tons |
| Texarkana, AR | 66 mi | 100°F | 3.5 tons |
Of 39 Arkansas cities here, Camden has the 17th highest cooling load. The range runs from Harrison at 33,100 BTU/hr to Fort Smith at 44,000.
Where Camden's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Camden 1, 2.1 miles from the center of Camden at 116 ft above sea level. That is close enough that the station's summers are Camden's summers.
No other city in this set uses Camden 1, so this sizing is Camden's alone.
The sun over Camden in late July
At 33.57°N, the noon sun on 21 July stands 76.8° above the horizon over Camden and the day runs 13 h 54 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
10,116 people live in Camden, the 39th largest of the 39 Arkansas cities sized on this site. Coordinates used: 33.5677, -92.8491.
Camden AC sizing questions
What size AC does a 2,000 sq ft house in Camden, AR need?
About 3.5 tons, for a cooling load of 39,500 BTU/hr on a 99°F design day. That is one ton per 607 square feet in Camden's climate.
Is 20 BTU per square foot right for Camden?
The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Camden 1. For a single room here, plan on 19.8 BTU/hr per square foot.
What does central AC cost to run in Camden?
About $412 a year: 3,002 kWh at SEER2 14.3 and 13.74¢ per kWh, over 7 cooling months.