What size AC for Cambridge, MN? 2 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Cambridge needs
2 tons central AC or heat pump, about 24,900 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 69% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 965 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Cambridge (0.5 mi away). Jul is the hottest month, averaging a high of 81.8°F and a low of 60.7°F, with about 5 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.
What it costs to run
About 712 kWh a year at SEER2 14.3, or roughly $117 at Minnesota's average residential rate of 16.44¢ per kWh. Cooling runs 3 months of the year here.
What drives the load in Cambridge
Of the 24,900 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (32%), 13,000 is sun on the house (52%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Cambridge's summer air (7%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.
Other house sizes in Cambridge
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 13,600 | 1.5 tons | 2 tons |
| 1,500 sq ft | 19,200 | 1.5 tons | 2.5 tons |
| 2,500 sq ft | 30,500 | 2.5 tons | 5 tons |
| 3,000 sq ft | 36,200 | 3 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.
Month by month in Cambridge
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 21.9°F | 0 | 0 |
| Feb | 27.1°F | 0 | 0 |
| Mar | 40.4°F | 0 | 0 |
| Apr | 56°F | 1 | 2 |
| May | 68.8°F | 27 | 35 |
| Jun | 77.4°F | 115 | 150 |
| Jul | 81.8°F | 205 | 268 |
| Aug | 79.8°F | 147 | 192 |
| Sep | 71.5°F | 48 | 62 |
| Oct | 57.7°F | 3 | 3 |
| Nov | 41.1°F | 0 | 0 |
| Dec | 26.9°F | 0 | 0 |
Jul alone uses 38% of the year's cooling energy. The unit runs the equivalent of 409 hours a year at full output.
Cambridge against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| North Branch, MN | 14 mi | 87°F | 2 tons |
| East Bethel, MN | 14 mi | 84°F | 2 tons |
| Ham Lake, MN | 21 mi | 88°F | 2.5 tons |
| Andover, MN | 22 mi | 88°F | 2.5 tons |
| Elk River, MN | 23 mi | 88°F | 2.5 tons |
| Ramsey, MN | 23 mi | 88°F | 2.5 tons |
Of 103 Minnesota cities here, Cambridge has the 89th highest cooling load. The range runs from Hibbing at 20,200 BTU/hr to Winona at 29,000.
Where Cambridge's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Cambridge, 0.5 miles from the center of Cambridge at 965 ft above sea level. That is close enough that the station's summers are Cambridge's summers.
No other city in this set uses Cambridge, so this sizing is Cambridge's alone.
The sun over Cambridge in late July
At 45.56°N, the noon sun on 21 July stands 64.8° above the horizon over Cambridge and the day runs 14 h 58 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
10,974 people live in Cambridge, the 98th largest of the 103 Minnesota cities sized on this site. Coordinates used: 45.5608, -93.2277.
Cambridge AC sizing questions
What size AC does a 2,000 sq ft house in Cambridge, MN need?
About 2 tons, for a cooling load of 24,900 BTU/hr on a 86°F design day. That is one ton per 965 square feet in Cambridge's climate.
Is 20 BTU per square foot right for Cambridge?
The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Cambridge. For a single room here, plan on 12.4 BTU/hr per square foot.
What does central AC cost to run in Cambridge?
About $117 a year: 712 kWh at SEER2 14.3 and 16.44¢ per kWh, over 3 cooling months.