ACSizeCheck

What size AC for Camarillo, CA? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Camarillo needs

2 tons central AC or heat pump, about 23,300 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 80% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,029 square feet in this climate. For a single room, size by the room: 11.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Camarillo Airport (3.2 mi away). Sep is the hottest month, averaging a high of 79.6°F and a low of 59.4°F, with about 9 days a year at 90°F or more. That gives a design temperature of 84°F against 75°F inside.

What it costs to run

About 839 kWh a year at SEER2 14.3, or roughly $273 at California's average residential rate of 32.58¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Camarillo

Of the 23,300 BTU/hr, 6,480 comes through walls, roof and windows on a 84°F afternoon (28%), 13,000 is sun on the house (56%), 2,120 is four people and their appliances, and 1,700 is moisture the coil has to wring out of Camarillo's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 21,600 BTU/hr before the moisture allowance.

Other house sizes in Camarillo

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft12,8001.5 tons2 tons
1,500 sq ft18,1001.5 tons2.5 tons
2,500 sq ft28,6002.5 tons5 tons
3,000 sq ft33,8003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,800 BTU/hr; a 350 sq ft living room needs about 4,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,000 BTU/hr.

Month by month in Camarillo

MonthAvg highCooling degree daysAC kWh
Jan68°F1114
Feb67.6°F810
Mar68.5°F710
Apr71°F1418
May71.9°F2026
Jun74.7°F5166
Jul78°F132172
Aug79.5°F163212
Sep79.6°F142185
Oct76.4°F6686
Nov72.8°F2634
Dec67.7°F56

Aug alone uses 25% of the year's cooling energy. The unit runs the equivalent of 514 hours a year at full output.

Camarillo against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Thousand Oaks, CA9 mi84°F2 tons
Santa Paula, CA9 mi84°F2 tons
Moorpark, CA10 mi84°F2 tons
Oxnard, CA10 mi78°F1.5 tons
Port Hueneme, CA11 mi78°F1.5 tons
San Buenaventura (Ventura), CA13 mi78°F1.5 tons

Of 376 California cities here, Camarillo has the 274th highest cooling load. The range runs from Corte Madera at 15,700 BTU/hr to Palm Desert at 59,000.

Where Camarillo's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Camarillo Airport, 3.2 miles from the center of Camarillo at 71 ft above sea level. That is close enough that the station's summers are Camarillo's summers.

4 other cities use the same station and get the same climate inputs. The closest to Camarillo: Thousand Oaks (9 mi away, 12.3 mi from the station), Santa Paula (9 mi away, 10 mi from the station), Moorpark (10 mi away, 13.1 mi from the station), Fillmore (14 mi away, 16.2 mi from the station). Camarillo sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Camarillo in late July

At 34.22°N, the noon sun on 21 July stands 76.2° above the horizon over Camarillo and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

69,881 people live in Camarillo, the 127th largest of the 376 California cities sized on this site. Coordinates used: 34.2218, -119.0322.

Camarillo AC sizing questions

What size AC does a 2,000 sq ft house in Camarillo, CA need?

About 2 tons, for a cooling load of 23,300 BTU/hr on a 84°F design day. That is one ton per 1,029 square feet in Camarillo's climate.

Is 20 BTU per square foot right for Camarillo?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Camarillo Airport. For a single room here, plan on 11.7 BTU/hr per square foot.

What does central AC cost to run in Camarillo?

About $273 a year: 839 kWh at SEER2 14.3 and 32.58¢ per kWh, over 5 cooling months.