What size AC for Burleson, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Burleson needs
4 tons central AC or heat pump, about 42,200 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 569 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Burleson (1.3 mi away). Aug is the hottest month, averaging a high of 95.2°F and a low of 71.8°F, with about 98 days a year at 90°F or more. That gives a design temperature of 102°F against 75°F inside.
What it costs to run
About 3,560 kWh a year at SEER2 14.3, or roughly $571 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Burleson
Of the 42,200 BTU/hr, 19,440 comes through walls, roof and windows on a 102°F afternoon (46%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 7,600 is moisture the coil has to wring out of Burleson's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 34,560 BTU/hr before the moisture allowance.
Other house sizes in Burleson
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 22,400 | 2 tons | 2 tons |
| 1,500 sq ft | 32,300 | 3 tons | 2.5 tons |
| 2,500 sq ft | 52,100 | 4 tons | 5 tons |
| 3,000 sq ft | 62,000 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.
Month by month in Burleson
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 56.8°F | 1 | 2 |
| Feb | 60.8°F | 4 | 5 |
| Mar | 68°F | 21 | 31 |
| Apr | 75.8°F | 74 | 109 |
| May | 82.8°F | 233 | 344 |
| Jun | 90.6°F | 441 | 650 |
| Jul | 94.7°F | 569 | 839 |
| Aug | 95.2°F | 573 | 845 |
| Sep | 88.5°F | 355 | 523 |
| Oct | 78.3°F | 123 | 181 |
| Nov | 66.9°F | 19 | 28 |
| Dec | 58.3°F | 2 | 3 |
Aug alone uses 24% of the year's cooling energy. The unit runs the equivalent of 1,208 hours a year at full output.
Burleson against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Crowley, TX | 5 mi | 105°F | 4 tons |
| Forest Hill, TX | 11 mi | 104°F | 4 tons |
| Kennedale, TX | 11 mi | 104°F | 4 tons |
| Cleburne, TX | 12 mi | 103°F | 4 tons |
| Mansfield, TX | 12 mi | 104°F | 4 tons |
| Benbrook, TX | 14 mi | 105°F | 4 tons |
Of 252 Texas cities here, Burleson has the 224th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Burleson's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Burleson, 1.3 miles from the center of Burleson at 762 ft above sea level. That is close enough that the station's summers are Burleson's summers.
No other city in this set uses Burleson, so this sizing is Burleson's alone.
The sun over Burleson in late July
At 32.51°N, the noon sun on 21 July stands 77.9° above the horizon over Burleson and the day runs 13 h 50 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
56,253 people live in Burleson, the 68th largest of the 252 Texas cities sized on this site. Coordinates used: 32.5144, -97.3233.
Burleson AC sizing questions
What size AC does a 2,000 sq ft house in Burleson, TX need?
About 4 tons, for a cooling load of 42,200 BTU/hr on a 102°F design day. That is one ton per 569 square feet in Burleson's climate.
Is 20 BTU per square foot right for Burleson?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Burleson. For a single room here, plan on 21.1 BTU/hr per square foot.
What does central AC cost to run in Burleson?
About $571 a year: 3,560 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.