ACSizeCheck

What size AC for Bucyrus, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Bucyrus needs

2.5 tons central AC or heat pump, about 26,400 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 908 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Marion Municipal Airport (14 mi away). Jul is the hottest month, averaging a high of 83.6°F and a low of 62.4°F, with about 12 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 1,017 kWh a year at SEER2 14.3, or roughly $191 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Bucyrus

Of the 26,400 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (35%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Bucyrus's summer air (8%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in Bucyrus

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,4001.5 tons2 tons
1,500 sq ft20,4002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Bucyrus

MonthAvg highCooling degree daysAC kWh
Jan34.3°F00
Feb37.4°F00
Mar47.9°F11
Apr61.3°F67
May72.1°F5673
Jun80.2°F173226
Jul83.6°F252328
Aug81.8°F199260
Sep75.9°F80105
Oct63.7°F1316
Nov50°F00
Dec38.8°F00

Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 550 hours a year at full output.

Bucyrus against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Galion, OH11 mi87°F2 tons
Marion, OH16 mi88°F2.5 tons
Mansfield, OH23 mi87°F2 tons
Tiffin, OH24 mi88°F2.5 tons
Fostoria, OH34 mi90°F2.5 tons
Ashland, OH35 mi87°F2 tons

Of 176 Ohio cities here, Bucyrus has the 129th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Bucyrus's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Marion Municipal Airport, 14 miles from the center of Bucyrus at 985 ft above sea level. That is close enough that the station's summers are Bucyrus's summers.

1 other city uses the same station and get the same climate inputs. The closest to Bucyrus: Marion (16 mi away, 3.2 mi from the station). Bucyrus is farther from the station than 1 of them.

The sun over Bucyrus in late July

At 40.81°N, the noon sun on 21 July stands 69.6° above the horizon over Bucyrus and the day runs 14 h 30 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

11,567 people live in Bucyrus, the 155th largest of the 176 Ohio cities sized on this site. Coordinates used: 40.8051, -82.9716.

Bucyrus AC sizing questions

What size AC does a 2,000 sq ft house in Bucyrus, OH need?

About 2.5 tons, for a cooling load of 26,400 BTU/hr on a 88°F design day. That is one ton per 908 square feet in Bucyrus's climate.

Is 20 BTU per square foot right for Bucyrus?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Marion Municipal Airport. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in Bucyrus?

About $191 a year: 1,017 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.