ACSizeCheck

What size AC for Bogalusa, LA? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Bogalusa needs

4 tons central AC or heat pump, about 42,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 570 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Bogalusa (0.5 mi away). Jul is the hottest month, averaging a high of 92.4°F and a low of 72.1°F, with about 88 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 4,119 kWh a year at SEER2 14.3, or roughly $547 at Louisiana's average residential rate of 13.27¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Bogalusa

Of the 42,100 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (41%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 9,700 is moisture the coil has to wring out of Bogalusa's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Bogalusa

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,4002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,0004 tons5 tons
3,000 sq ft61,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in Bogalusa

MonthAvg highCooling degree daysAC kWh
Jan61.3°F812
Feb65.8°F1524
Mar72.1°F4368
Apr78.9°F124194
May85.4°F294461
Jun90.5°F459721
Jul92.4°F535840
Aug92°F525825
Sep88.8°F398625
Oct81°F173272
Nov70.8°F3657
Dec63.9°F1219

Jul alone uses 20% of the year's cooling energy. The unit runs the equivalent of 1,399 hours a year at full output.

Bogalusa against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Picayune, MS20 mi98°F3.5 tons
Covington, LA25 mi97°F3.5 tons
Mandeville, LA31 mi98°F3.5 tons
Slidell, LA34 mi98°F3.5 tons
Hammond, LA40 mi99°F3.5 tons
Bay St. Louis, MS43 mi95°F3.5 tons

Of 35 Louisiana cities here, Bogalusa has the 21st highest cooling load. The range runs from Covington at 37,800 BTU/hr to Natchitoches at 45,900.

Where Bogalusa's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Bogalusa, 0.5 miles from the center of Bogalusa at 100 ft above sea level. That is close enough that the station's summers are Bogalusa's summers.

No other city in this set uses Bogalusa, so this sizing is Bogalusa's alone.

The sun over Bogalusa in late July

At 30.77°N, the noon sun on 21 July stands 79.6° above the horizon over Bogalusa and the day runs 13 h 42 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

10,367 people live in Bogalusa, the 35th largest of the 35 Louisiana cities sized on this site. Coordinates used: 30.7749, -89.8619.

Bogalusa AC sizing questions

What size AC does a 2,000 sq ft house in Bogalusa, LA need?

About 4 tons, for a cooling load of 42,100 BTU/hr on a 99°F design day. That is one ton per 570 square feet in Bogalusa's climate.

Is 20 BTU per square foot right for Bogalusa?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Bogalusa. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in Bogalusa?

About $547 a year: 4,119 kWh at SEER2 14.3 and 13.27¢ per kWh, over 7 cooling months.