What size AC for Berea, KY? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Berea needs
3 tons central AC or heat pump, about 31,500 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 33% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 763 square feet in this climate. For a single room, size by the room: 15.7 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Berea College (1.1 mi away). Jul is the hottest month, averaging a high of 86.8°F and a low of 67.3°F, with about 21 days a year at 90°F or more. That gives a design temperature of 92°F against 75°F inside.
What it costs to run
About 1,928 kWh a year at SEER2 14.3, or roughly $274 at Kentucky's average residential rate of 14.2¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Berea
Of the 31,500 BTU/hr, 12,240 comes through walls, roof and windows on a 92°F afternoon (39%), 13,000 is sun on the house (41%), 2,120 is four people and their appliances, and 4,100 is moisture the coil has to wring out of Berea's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 27,360 BTU/hr before the moisture allowance.
Other house sizes in Berea
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 17,000 | 1.5 tons | 2 tons |
| 1,500 sq ft | 24,200 | 2 tons | 2.5 tons |
| 2,500 sq ft | 38,700 | 3.5 tons | 5 tons |
| 3,000 sq ft | 46,000 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,400 BTU/hr.
Month by month in Berea
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 45.3°F | 0 | 0 |
| Feb | 50.6°F | 1 | 1 |
| Mar | 59.7°F | 7 | 9 |
| Apr | 70.4°F | 43 | 60 |
| May | 77.6°F | 133 | 184 |
| Jun | 83.9°F | 277 | 385 |
| Jul | 86.8°F | 374 | 519 |
| Aug | 85.8°F | 336 | 466 |
| Sep | 79.9°F | 178 | 247 |
| Oct | 69.9°F | 35 | 49 |
| Nov | 57.8°F | 5 | 7 |
| Dec | 48.7°F | 0 | 0 |
Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 876 hours a year at full output.
Berea against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Richmond, KY | 10 mi | 92°F | 3 tons |
| Nicholasville, KY | 26 mi | 92°F | 3 tons |
| Danville, KY | 27 mi | 91°F | 2.5 tons |
| Winchester, KY | 29 mi | 92°F | 3 tons |
| Lexington-Fayette urban county, KY | 32 mi | 92°F | 3 tons |
| Somerset, KY | 39 mi | 91°F | 3 tons |
Of 42 Kentucky cities here, Berea has the 26th highest cooling load. The range runs from Versailles at 29,000 BTU/hr to Paducah at 36,900.
Where Berea's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Berea College, 1.1 miles from the center of Berea at 1,070 ft above sea level. That is close enough that the station's summers are Berea's summers.
No other city in this set uses Berea College, so this sizing is Berea's alone.
The sun over Berea in late July
At 37.59°N, the noon sun on 21 July stands 72.8° above the horizon over Berea and the day runs 14 h 13 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
16,436 people live in Berea, the 28th largest of the 42 Kentucky cities sized on this site. Coordinates used: 37.5893, -84.2945.
Berea AC sizing questions
What size AC does a 2,000 sq ft house in Berea, KY need?
About 3 tons, for a cooling load of 31,500 BTU/hr on a 92°F design day. That is one ton per 763 square feet in Berea's climate.
Is 20 BTU per square foot right for Berea?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Berea College. For a single room here, plan on 15.7 BTU/hr per square foot.
What does central AC cost to run in Berea?
About $274 a year: 1,928 kWh at SEER2 14.3 and 14.2¢ per kWh, over 5 cooling months.