ACSizeCheck

What size AC for Bellwood, IL? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Bellwood needs

2.5 tons central AC or heat pump, about 29,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 45% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 828 square feet in this climate. For a single room, size by the room: 14.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Chicago Ohare International Airport (6.1 mi away). Jul is the hottest month, averaging a high of 84.5°F and a low of 66.4°F, with about 17 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 1,394 kWh a year at SEER2 14.3, or roughly $268 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Bellwood

Of the 29,000 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (35%), 13,000 is sun on the house (45%), 2,120 is four people and their appliances, and 3,800 is moisture the coil has to wring out of Bellwood's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Bellwood

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,7001.5 tons2 tons
1,500 sq ft22,3002 tons2.5 tons
2,500 sq ft35,6003 tons5 tons
3,000 sq ft42,3004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,700 BTU/hr.

Month by month in Bellwood

MonthAvg highCooling degree daysAC kWh
Jan31.6°F00
Feb35.7°F00
Mar47°F23
Apr59°F811
May70.5°F6083
Jun80.4°F199277
Jul84.5°F326452
Aug82.5°F277385
Sep75.5°F116161
Oct62.7°F1521
Nov48.4°F01
Dec36.6°F00

Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 688 hours a year at full output.

Bellwood against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Melrose Park, IL2 mi89°F2.5 tons
Maywood, IL2 mi89°F2.5 tons
Westchester, IL2 mi89°F2.5 tons
Northlake, IL3 mi89°F2.5 tons
River Forest, IL3 mi89°F2.5 tons
Forest Park, IL3 mi90°F2.5 tons

Of 225 Illinois cities here, Bellwood has the 141st highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.

Where Bellwood's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Chicago Ohare International Airport, 6.1 miles from the center of Bellwood at 672 ft above sea level. That is close enough that the station's summers are Bellwood's summers.

27 other cities use the same station and get the same climate inputs. The closest to Bellwood: Melrose Park (2 mi away, 5.3 mi from the station), Maywood (2 mi away, 7.2 mi from the station), Westchester (2 mi away, 8 mi from the station), Northlake (3 mi away, 3.5 mi from the station), River Forest (3 mi away, 7.3 mi from the station). Bellwood is farther from the station than 14 of them.

The sun over Bellwood in late July

At 41.88°N, the noon sun on 21 July stands 68.5° above the horizon over Bellwood and the day runs 14 h 36 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

18,132 people live in Bellwood, the 139th largest of the 225 Illinois cities sized on this site. Coordinates used: 41.8829, -87.8762.

Bellwood AC sizing questions

What size AC does a 2,000 sq ft house in Bellwood, IL need?

About 2.5 tons, for a cooling load of 29,000 BTU/hr on a 89°F design day. That is one ton per 828 square feet in Bellwood's climate.

Is 20 BTU per square foot right for Bellwood?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago Ohare International Airport. For a single room here, plan on 14.5 BTU/hr per square foot.

What does central AC cost to run in Bellwood?

About $268 a year: 1,394 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.