What size AC for Beaumont, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Beaumont needs
4 tons central AC or heat pump, about 43,100 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.6 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 557 square feet in this climate. For a single room, size by the room: 21.5 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Port Arthur Se Tx Regional Airport (11.6 mi away). Aug is the hottest month, averaging a high of 93.1°F and a low of 74.4°F, with about 93 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.
What it costs to run
About 4,831 kWh a year at SEER2 14.3, or roughly $774 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.
What drives the load in Beaumont
Of the 43,100 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (42%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 9,900 is moisture the coil has to wring out of Beaumont's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.
Other house sizes in Beaumont
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 22,900 | 2 tons | 2 tons |
| 1,500 sq ft | 33,000 | 3 tons | 2.5 tons |
| 2,500 sq ft | 53,100 | 5 tons | 5 tons |
| 3,000 sq ft | 63,200 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,900 BTU/hr.
Month by month in Beaumont
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 63.5°F | 15 | 23 |
| Feb | 67.3°F | 26 | 41 |
| Mar | 73.2°F | 72 | 113 |
| Apr | 79°F | 162 | 254 |
| May | 85.7°F | 358 | 563 |
| Jun | 90.9°F | 510 | 801 |
| Jul | 92.6°F | 577 | 906 |
| Aug | 93.1°F | 581 | 913 |
| Sep | 89.5°F | 452 | 709 |
| Oct | 82.1°F | 231 | 363 |
| Nov | 72.3°F | 65 | 103 |
| Dec | 65.5°F | 27 | 43 |
Aug alone uses 19% of the year's cooling energy. The unit runs the equivalent of 1,605 hours a year at full output.
Beaumont against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Nederland, TX | 12 mi | 100°F | 4 tons |
| Lumberton, TX | 12 mi | 101°F | 4 tons |
| Port Neches, TX | 14 mi | 100°F | 4 tons |
| Groves, TX | 17 mi | 100°F | 4 tons |
| Port Arthur, TX | 20 mi | 100°F | 4 tons |
| Orange, TX | 24 mi | 100°F | 4 tons |
Of 252 Texas cities here, Beaumont has the 206th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Beaumont's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Port Arthur Se Tx Regional Airport, 11.6 miles from the center of Beaumont at 13 ft above sea level. That is close enough that the station's summers are Beaumont's summers.
5 other cities use the same station and get the same climate inputs. The closest to Beaumont: Nederland (12 mi away, 1.9 mi from the station), Port Neches (14 mi away, 3.9 mi from the station), Groves (17 mi away, 6.6 mi from the station), Port Arthur (20 mi away, 8.7 mi from the station), Orange (24 mi away, 20.1 mi from the station). Beaumont is farther from the station than 4 of them.
The sun over Beaumont in late July
At 30.08°N, the noon sun on 21 July stands 80.3° above the horizon over Beaumont and the day runs 13 h 40 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.
112,893 people live in Beaumont, the 38th largest of the 252 Texas cities sized on this site. Coordinates used: 30.0849, -94.1453.
Beaumont AC sizing questions
What size AC does a 2,000 sq ft house in Beaumont, TX need?
About 4 tons, for a cooling load of 43,100 BTU/hr on a 100°F design day. That is one ton per 557 square feet in Beaumont's climate.
Is 20 BTU per square foot right for Beaumont?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Port Arthur Se Tx Regional Airport. For a single room here, plan on 21.5 BTU/hr per square foot.
What does central AC cost to run in Beaumont?
About $774 a year: 4,831 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.