ACSizeCheck

What size AC for Battle Ground, WA? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Battle Ground needs

2 tons central AC or heat pump, about 24,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 75% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,002 square feet in this climate. For a single room, size by the room: 12 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Vancouver Pearson Airport (12.1 mi away). Aug is the hottest month, averaging a high of 81.6°F and a low of 57.2°F, with about 15 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 502 kWh a year at SEER2 14.3, or roughly $72 at Washington's average residential rate of 14.42¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Battle Ground

Of the 24,000 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (33%), 13,000 is sun on the house (54%), 2,120 is four people and their appliances, and 900 is moisture the coil has to wring out of Battle Ground's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Battle Ground

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,1001.5 tons2 tons
1,500 sq ft18,5001.5 tons2.5 tons
2,500 sq ft29,4002.5 tons5 tons
3,000 sq ft34,8003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,800 BTU/hr; a 350 sq ft living room needs about 4,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,200 BTU/hr.

Month by month in Battle Ground

MonthAvg highCooling degree daysAC kWh
Jan47°F00
Feb51°F00
Mar56.1°F00
Apr61.2°F11
May68.3°F1418
Jun73.5°F4355
Jul80.9°F139175
Aug81.6°F149187
Sep75.8°F5164
Oct63.7°F22
Nov53°F00
Dec46.5°F00

Aug alone uses 37% of the year's cooling energy. The unit runs the equivalent of 300 hours a year at full output.

Battle Ground against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Ridgefield, WA7 mi86°F2 tons
Vancouver, WA10 mi87°F2 tons
Camas, WA13 mi87°F2 tons
St. Helens, OR14 mi86°F2 tons
Washougal, WA16 mi87°F2 tons
Fairview, OR17 mi87°F2 tons

Of 91 Washington cities here, Battle Ground has the 22nd highest cooling load. The range runs from Burlington at 15,700 BTU/hr to Kennewick at 32,900.

Where Battle Ground's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Vancouver Pearson Airport, 12.1 miles from the center of Battle Ground at 21 ft above sea level. That is close enough that the station's summers are Battle Ground's summers.

No other city in this set uses Vancouver Pearson Airport, so this sizing is Battle Ground's alone.

The sun over Battle Ground in late July

At 45.78°N, the noon sun on 21 July stands 64.6° above the horizon over Battle Ground and the day runs 14 h 60 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

22,959 people live in Battle Ground, the 50th largest of the 91 Washington cities sized on this site. Coordinates used: 45.7768, -122.5410.

Battle Ground AC sizing questions

What size AC does a 2,000 sq ft house in Battle Ground, WA need?

About 2 tons, for a cooling load of 24,000 BTU/hr on a 86°F design day. That is one ton per 1,002 square feet in Battle Ground's climate.

Is 20 BTU per square foot right for Battle Ground?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Vancouver Pearson Airport. For a single room here, plan on 12 BTU/hr per square foot.

What does central AC cost to run in Battle Ground?

About $72 a year: 502 kWh at SEER2 14.3 and 14.42¢ per kWh, over 3 cooling months.