What size AC for Augusta, ME? 2 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Augusta needs
2 tons central AC or heat pump, about 23,300 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 80% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,029 square feet in this climate. For a single room, size by the room: 11.7 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Augusta State Airport (3.4 mi away). Jul is the hottest month, averaging a high of 79.9°F and a low of 60.3°F, with about 5 days a year at 90°F or more. That gives a design temperature of 84°F against 75°F inside.
What it costs to run
About 558 kWh a year at SEER2 14.3, or roughly $169 at Maine's average residential rate of 30.23¢ per kWh. Cooling runs 3 months of the year here.
What drives the load in Augusta
Of the 23,300 BTU/hr, 6,480 comes through walls, roof and windows on a 84°F afternoon (28%), 13,000 is sun on the house (56%), 2,120 is four people and their appliances, and 1,700 is moisture the coil has to wring out of Augusta's summer air (7%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 21,600 BTU/hr before the moisture allowance.
Other house sizes in Augusta
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 12,800 | 1.5 tons | 2 tons |
| 1,500 sq ft | 18,100 | 1.5 tons | 2.5 tons |
| 2,500 sq ft | 28,600 | 2.5 tons | 5 tons |
| 3,000 sq ft | 33,800 | 3 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,800 BTU/hr; a 350 sq ft living room needs about 4,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,000 BTU/hr.
Month by month in Augusta
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 28.8°F | 0 | 0 |
| Feb | 31.9°F | 0 | 0 |
| Mar | 40.6°F | 0 | 0 |
| Apr | 53.5°F | 0 | 1 |
| May | 65.8°F | 11 | 14 |
| Jun | 74.4°F | 67 | 88 |
| Jul | 79.9°F | 171 | 223 |
| Aug | 78.9°F | 139 | 181 |
| Sep | 70.9°F | 38 | 50 |
| Oct | 57.9°F | 2 | 2 |
| Nov | 45.7°F | 0 | 0 |
| Dec | 34.7°F | 0 | 0 |
Jul alone uses 40% of the year's cooling energy. The unit runs the equivalent of 342 hours a year at full output.
Augusta against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Waterville, ME | 15 mi | 84°F | 2 tons |
| Lewiston, ME | 28 mi | 84°F | 2 tons |
| Auburn, ME | 31 mi | 84°F | 2 tons |
| Westbrook, ME | 53 mi | 84°F | 2 tons |
| Portland, ME | 53 mi | 84°F | 2 tons |
| South Portland, ME | 56 mi | 84°F | 2 tons |
Of 11 Maine cities here, Augusta has the 10th highest cooling load. The range runs from Waterville at 23,300 BTU/hr to Sanford at 24,900.
Where Augusta's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Augusta State Airport, 3.4 miles from the center of Augusta at 349 ft above sea level. That is close enough that the station's summers are Augusta's summers.
No other city in this set uses Augusta State Airport, so this sizing is Augusta's alone.
The sun over Augusta in late July
At 44.33°N, the noon sun on 21 July stands 66.1° above the horizon over Augusta and the day runs 14 h 50 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
19,168 people live in Augusta, the 10th largest of the 11 Maine cities sized on this site. Coordinates used: 44.3349, -69.7342.
Augusta AC sizing questions
What size AC does a 2,000 sq ft house in Augusta, ME need?
About 2 tons, for a cooling load of 23,300 BTU/hr on a 84°F design day. That is one ton per 1,029 square feet in Augusta's climate.
Is 20 BTU per square foot right for Augusta?
The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Augusta State Airport. For a single room here, plan on 11.7 BTU/hr per square foot.
What does central AC cost to run in Augusta?
About $169 a year: 558 kWh at SEER2 14.3 and 30.23¢ per kWh, over 3 cooling months.