ACSizeCheck

What size AC for Ashland, KY? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Ashland needs

2.5 tons central AC or heat pump, about 30,600 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 37% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 783 square feet in this climate. For a single room, size by the room: 15.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Huntington Tri-State Airport (8.1 mi away). Jul is the hottest month, averaging a high of 86.4°F and a low of 66.4°F, with about 25 days a year at 90°F or more. That gives a design temperature of 91°F against 75°F inside.

What it costs to run

About 1,715 kWh a year at SEER2 14.3, or roughly $244 at Kentucky's average residential rate of 14.2¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Ashland

Of the 30,600 BTU/hr, 11,520 comes through walls, roof and windows on a 91°F afternoon (38%), 13,000 is sun on the house (42%), 2,120 is four people and their appliances, and 4,000 is moisture the coil has to wring out of Ashland's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 26,640 BTU/hr before the moisture allowance.

Other house sizes in Ashland

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,5001.5 tons2 tons
1,500 sq ft23,6002 tons2.5 tons
2,500 sq ft37,7003.5 tons5 tons
3,000 sq ft44,7004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,300 BTU/hr; a 350 sq ft living room needs about 5,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,200 BTU/hr.

Month by month in Ashland

MonthAvg highCooling degree daysAC kWh
Jan43.2°F00
Feb47.3°F00
Mar56.8°F68
Apr68.8°F3143
May76.2°F103143
Jun83.3°F244339
Jul86.4°F354491
Aug85.5°F316438
Sep79.6°F153212
Oct68.6°F2636
Nov56.6°F23
Dec46.7°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 801 hours a year at full output.

Ashland against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Ironton, OH5 mi91°F2.5 tons
Huntington, WV12 mi91°F2.5 tons
Portsmouth, OH26 mi92°F3 tons
St. Albans, WV45 mi91°F2.5 tons
South Charleston, WV51 mi91°F2.5 tons
Charleston, WV55 mi91°F2.5 tons

Of 42 Kentucky cities here, Ashland has the 33rd highest cooling load. The range runs from Versailles at 29,000 BTU/hr to Paducah at 36,900.

Where Ashland's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Huntington Tri-State Airport, across the line in West Virginia, 8.1 miles from the center of Ashland at 824 ft above sea level. That is close enough that the station's summers are Ashland's summers.

2 other cities use the same station and get the same climate inputs. The closest to Ashland: Ironton (5 mi away, 13.3 mi from the station), Huntington (12 mi away, 7.2 mi from the station). Ashland is farther from the station than 1 of them.

The sun over Ashland in late July

At 38.46°N, the noon sun on 21 July stands 71.9° above the horizon over Ashland and the day runs 14 h 17 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

21,066 people live in Ashland, the 18th largest of the 42 Kentucky cities sized on this site. Coordinates used: 38.4595, -82.6451.

Ashland AC sizing questions

What size AC does a 2,000 sq ft house in Ashland, KY need?

About 2.5 tons, for a cooling load of 30,600 BTU/hr on a 91°F design day. That is one ton per 783 square feet in Ashland's climate.

Is 20 BTU per square foot right for Ashland?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Huntington Tri-State Airport. For a single room here, plan on 15.3 BTU/hr per square foot.

What does central AC cost to run in Ashland?

About $244 a year: 1,715 kWh at SEER2 14.3 and 14.2¢ per kWh, over 5 cooling months.