What size AC for Arlington, WA? 2 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Arlington needs
2 tons central AC or heat pump, about 21,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 100% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,145 square feet in this climate. For a single room, size by the room: 10.5 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Arlington (2.2 mi away). Aug is the hottest month, averaging a high of 77.7°F and a low of 47.1°F, with about 5 days a year at 90°F or more. That gives a design temperature of 82°F against 75°F inside.
What it costs to run
About 69 kWh a year at SEER2 14.3, or roughly $10 at Washington's average residential rate of 14.42¢ per kWh. Cooling runs 0 months of the year here.
What drives the load in Arlington
Of the 21,000 BTU/hr, 5,040 comes through walls, roof and windows on a 82°F afternoon (24%), 13,000 is sun on the house (62%), 2,120 is four people and their appliances, and 800 is moisture the coil has to wring out of Arlington's summer air (4%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 20,160 BTU/hr before the moisture allowance.
Other house sizes in Arlington
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 11,600 | 1.5 tons | 2 tons |
| 1,500 sq ft | 16,300 | 1.5 tons | 2.5 tons |
| 2,500 sq ft | 25,700 | 2 tons | 5 tons |
| 3,000 sq ft | 30,300 | 2.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,600 BTU/hr; a 350 sq ft living room needs about 3,700 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 6,300 BTU/hr.
Month by month in Arlington
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 47.4°F | 0 | 0 |
| Feb | 50.5°F | 0 | 0 |
| Mar | 54.2°F | 0 | 0 |
| Apr | 59.8°F | 0 | 0 |
| May | 66.7°F | 0 | 0 |
| Jun | 71°F | 7 | 9 |
| Jul | 77.3°F | 23 | 29 |
| Aug | 77.7°F | 21 | 26 |
| Sep | 72°F | 3 | 4 |
| Oct | 60.8°F | 0 | 0 |
| Nov | 52.2°F | 0 | 0 |
| Dec | 46.1°F | 0 | 0 |
Jul alone uses 42% of the year's cooling energy. The unit runs the equivalent of 47 hours a year at full output.
Arlington against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Marysville, WA | 6 mi | 77°F | 1.5 tons |
| Lake Stevens, WA | 12 mi | 77°F | 1.5 tons |
| Everett, WA | 14 mi | 77°F | 1.5 tons |
| Snohomish, WA | 17 mi | 77°F | 1.5 tons |
| Mount Vernon, WA | 19 mi | 74°F | 1.5 tons |
| Mukilteo, WA | 19 mi | 77°F | 1.5 tons |
Of 91 Washington cities here, Arlington has the 46th highest cooling load. The range runs from Burlington at 15,700 BTU/hr to Kennewick at 32,900.
Where Arlington's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Arlington, 2.2 miles from the center of Arlington at 100 ft above sea level. That is close enough that the station's summers are Arlington's summers.
No other city in this set uses Arlington, so this sizing is Arlington's alone.
The sun over Arlington in late July
At 48.17°N, the noon sun on 21 July stands 62.2° above the horizon over Arlington and the day runs 15 h 16 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
21,959 people live in Arlington, the 52nd largest of the 91 Washington cities sized on this site. Coordinates used: 48.1704, -122.1446.
Arlington AC sizing questions
What size AC does a 2,000 sq ft house in Arlington, WA need?
About 2 tons, for a cooling load of 21,000 BTU/hr on a 82°F design day. That is one ton per 1,145 square feet in Arlington's climate.
Is 20 BTU per square foot right for Arlington?
The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Arlington. For a single room here, plan on 10.5 BTU/hr per square foot.
What does central AC cost to run in Arlington?
About $10 a year: 69 kWh at SEER2 14.3 and 14.42¢ per kWh, over 0 cooling months.